Phase-Sensitive Radar Using ADALM-Pluto SDR and Cantenna for Sub-Millimeter Displacement Measurement

Authors

  • Eril Mozef Politeknik Negeri Bandung
  • Ridho Shofwan Rasyid Politeknik Negeri Bandung
  • Enceng Sulaeman Politeknik Negeri Bandung
  • Tiyo Rizky Mulyana Politeknik Negeri Bandung
  • Fahrizal Al Farik Politeknik Negeri Bandung
  • Thaskia Qolbi Junjunan Politeknik Negeri Bandung

DOI:

https://doi.org/10.55981/jet.757

Keywords:

phase-sensitive radar, software-defined radio, sub-millimeter-displacement measurement, cantenna directional antenna, non-contact human respiratory monitoring.

Abstract

The capability of phase-sensitive radar to detect sub-millimeter displacement has been widely demonstrated, enabling a range of applications such as structural vibration monitoring, human vital-sign detection, gesture sensing, and precision motion tracking. In these domains, particularly in non-contact human respiratory monitoring, conventional phase-sensitive radar systems offer key advantages, including high phase stability, robust performance under non-ideal lighting or environmental conditions, and the ability to operate without physical contact. These strengths make them effective for capturing small periodic chest movements required for accurate respiratory assessment. However, conventional hardware implementations often suffer from limited flexibility, higher development cost, and increased design complexity. These constraints motivate the shift toward software-defined radio (SDR) solutions, which provide reconfigurability, simplified prototyping, and significantly lower cost while retaining the essential phase-sensitive capabilities. This motivation forms the basis of the present research. This study realizes a phase-sensitive radar using an ADALM-Pluto SDR operating at 2.45 GHz with a cantenna antenna configuration. Compared with previous SDR-based works that focus primarily on Doppler vital-sign extraction or require more elaborate RF front-ends, the proposed system emphasizes displacement-resolution enhancement through careful phase processing while maintaining minimal hardware complexity. The combination of a compact SDR platform, simple antenna structure, and optimized signal processing pipeline yields a practical and accessible radar prototype. Experimental results demonstrate that the proposed system achieves a displacement resolution of 0.5 mm, meeting the requirements for developing a reliable respiratory-monitoring application and confirming the suitability of SDR-based phase-sensitive radar for low-cost biomedical sensing.

Downloads

Download data is not yet available.

References

A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, J. Lin, and G. T. A. Kovacs, “Range correlation and i/q performance benefits in single-chip silicon doppler radars for noncontact cardiopulmonary monitoring,” IEEE Trans. Microw. Theory Tech., vol. 52, no. 3, pp. 838–848, Mar. 2004, doi: 10.1109/TMTT.2004.823552. Crossref

M. S. Raheel et al., “Contactless vital sign monitoring systems: a comprehensive survey of remote health sensing for heart rate and respiration in internet of things and sleep applications,” Sensors & Diagnostics, vol. 3, no. 7, pp. 1085–1118, 2024, doi: 10.1039/D4SD00073K. Crossref

M.-C. Huang, J. J. Liu, W. Xu, C. Gu, C. Li, and M. Sarrafzadeh, “A self-calibrating radar sensor system for measuring vital signs,” IEEE Trans. Biomed. Circuits Syst., vol. 10, no. 2, pp. 352–363, Apr. 2016, doi: 10.1109/TBCAS.2015.2411732. Crossref

S. Costanzo, “Software-defined doppler radar sensor for human breathing detection,” Sensors, vol. 19, no. 14, p. 3085, Jul. 2019, doi: 10.3390/s19143085. Crossref

U. Saeed, Q. H. Abbasi, and S. A. Shah, “AI-driven lightweight real-time sdr sensing system for anomalous respiration identification using ensemble learning,” CCF Trans. Pervasive Comput. Interact., vol. 4, no. 4, pp. 381–392, Dec. 2022, doi: 10.1007/s42486-022-00113-6. Crossref

M. Rehman et al., “Enhancing system performance through objective feature scoring of multiple persons’ breathing using non-contact rf approach,” Sensors, vol. 23, no. 3, p. 1251, Jan. 2023, doi: 10.3390/s23031251. Crossref

E. Mozef, R. S. Rasyid, and E. Sulaeman, “Program aplikasi ratifa v.1.0 - radar sensitif fasa berbasis software-defined radio (sdr) adalm pluto dengan antena cantenna,” Reg. No. 000902787; App. No. EC002025062526, 2025. Crossref

C. A. Balanis, Antenna Theory: Analysis and Design, 4th ed. Hoboken, NJ, USA: John Wiley & Sons, Inc., 2016.

M. Elhefnawy, “Design and simulation of a doppler-radar rf front-end transceiver,” Adv. Sci. Technol. Eng. Syst. J., vol. 4, no. 5, pp. 250–257, 2019, doi: 10.25046/aj040531. Crossref

A. Harsh, “Measuring radar signatures of a simple pendulum using cantenna radar,” Int. J. Comput. Technol., vol. 15, no. 5, pp. 6785–6795, Apr. 2016, doi: 10.24297/ijct.v15i5.1653. Crossref

N. Schulz et al., “High-speed 1 thz photonic continuous wave phase-sensitive radar with micrometer precision,” J. Infrared, Millimeter, Terahertz Waves, vol. 46, no. 11, p. 76, Nov. 2025, doi: 10.1007/s10762-025-01095-z. Crossref

S. A. N. Saqueb, J. L. Garry, G. E. Smith, N. K. Nahar, and K. Sertel, “THz imaging using rail-based synthetic aperture radar for the detection of concealed objects,” in Usn. Nat. Radio Sci. Meet., 2018, pp. 175–176. doi: 10.1109/USNC-URSI.2018.8602878. Crossref

W. Liu, H. Wang, Q. Yang, B. Deng, L. Fan, and J. Yi, “High precision motion compensation thz-isar imaging algorithm based on kt and me-mn,” Remote Sens., vol. 15, no. 18, p. 4371, Sep. 2023, doi: 10.3390/rs15184371. Crossref

H. Kim and J. Jeong, “Non-contact measurement of human respiration and heartbeat using w-band doppler radar sensor,” Sensors, vol. 20, no. 18, p. 5209, Sep. 2020, doi: 10.3390/s20185209. Crossref

Downloads

Published

2025-12-31

Issue

Section

Articles

How to Cite

[1]
“Phase-Sensitive Radar Using ADALM-Pluto SDR and Cantenna for Sub-Millimeter Displacement Measurement”, J. Elektron. dan Telekomun., vol. 25, no. 2, pp. 126–140, Dec. 2025, doi: 10.55981/jet.757.